IC Realtime 2 Megapixel Mini Network PTZ Dome Camera (ICIPP2012S) User Manual

Page 12

Advertising
background image

4

Figure 2-3

There are two dial switch buttons on the PTZ. You can use them to set speed dome address,
baud rate, and parity respectively. It is 1 when you set the button as ON.
For the protocol dial switch, you can refer to the following sheet. 1 is the lowest bit and the 8 is
the highest bit.

Please note the intelligent speed dome can automatically recognize the industrial

standard protocol, PELCO-D. PELCO-P. Usually you do not need to set the protocol.

2.4.2 Baud Rate and Parity Setup

For the dial switch button 1-4. 1 and 2 is to set baud rate. 3 and 4 is to set parity. Please refer to
the following figure for detailed information. See Figure 2-4.

Figure 2-4

Please refer to the baud rate sheet for detailed information.

1

2

Baud Rate

OFF OFF 9600bps

ON

OFF 4800bps

OFF

ON

2400bps

ON ON 1200bps

Please refer to the parity setup sheet for detailed information.

3

4

Parity

OFF OFF NONE

ON

OFF EVEN

OFF ON ODD

Advertising
This manual is related to the following products: