UltraView UVC-6130-1 WDR Box Camera User Manual

Automatic shutter menu:

Select the parameters for high and low luminance conditions:

High Luminance: Sets the lux level for bright light conditions such as daylight.

Mode: When lens type is AUTO IRIS, you can choose SHUT+AUTO IRIS or
AUTO IRIS mode. When the lens type is manual, only SHUT mode is available.

Brightness: Select the brightness level to which the iris and shutter speed will
adjust automatically. The values range from 0 to 255.

Low luminance: Sets the lux level for low light conditions.

Mode:

Select Off, AGC, Slow, AGC→Slow, Slow→AGC, or AGC→Slow→AGC.

Brightness: Select the brightness level to X0.25, X0.50, X0.75 or X1.

AGC Max: Adjust the maximum automatic gain control level. The value can
range from 0 to 7.

Manual shutter menu:

Shutter: Set the manual shutter to 1/60(1/50), 1/100(1/120), 1/250, 1/500,
1/1000, 1/2000, 1/4000, 1/10000, 1/20000 or 1/50000. Select a higher value to
see movement and a lower value to see clearer images.

Low luminance: Sets the lux level for low light conditions

Mode: Only AGC available.

Brightness: Select the brightness level to X0.25, X0.50, X0.75 or X1.

AGC Max: Adjust the maximum automatic gain control level. The value can
range from 0 to 7.