6.4 Optional Switch Box

An optional remote switch box is available if you would like to manually control the roll
function and auto/manual function from a switch in the cab. The switch box and cable can be

ordered using the following part numbers:

Item

Part Number

Name

Quantity

C25

44602-01

BOX SWITCH UC4 REMOTE HAND CONTROL VER.1 RMR

1

C26

43240-26

CABLE UC5 SWITCH BOX

1

C27

44658-98

CABLE UC4 3M EXTENSION 16-PIN AMP

1

1. Disconnect the connector from cable C20 that is installed in the Thru 1 connector on the

input module. Remove the wedge from the face of the 12 pin Deutsch connector on C20.
The wedge is removed by inserting a small flat implement underneath the wedge and lifting
it up.

2. Remove the pin in position 2 and replace it with the Roll CW pin from C26. Remove the

pin in position 5 and replace it with the Roll CCW pin from C26. Insert the wedge back
into the plug. Connect the connector to the Thru 1 connector on the input module.

3. Remove P02 from the OEM 3 connector. Connect the 12 pin Deutsch plug on C26 to the

OEM 3 connector on the input module. Route the other end of the cable to the hitch of
the sprayer.

4. Attach the switch box (C25) inside the cab and connect it to cable C26. An extra label is

provided with the switch box if you prefer to remove the switches from the housing and
mount them in the existing sprayer switch panel.

* Some sprayer types may not use all the switch functions.

Figure 17: Switch Box Installation