Product interface and key introduction, Main unit port instructions – NOYAFA NF-8200 User Manual
Page 4
03
(5).Detecting cable types
STP/UTP 5E, 6E network cable, telephone cable,and common
metal wires connected with alligator clip.
(6).Operating environment temperature/humidity
-10
~ +60
/20% ~ 70%;
℃
℃
(7).Testing device interface
Main unit: RJ45 (M), RJ45 (S)loop interface, RJ11main interface;
Remote identifier: RJ45,
connector。
RJ11
(8).Length measurement
Range: 1-2500m;
Calibration precision: 2% (+/-0.5m, or +/-1.5 feet); (calibration;
cable >10m) measurement precision: 3% ((+/-0.5m, or +/-1.5 feet);
(AMP, CAT5E, 6E cable material)
Display unit: meter, inch, yard.
(9).Length calibration, storage and data load
User can set a length value at a known length, store the value in
the system,which can be used for future choice. and the calibration
length should be over 10m.
(10). Line sequence and cable failure positioning
Open, short, reverse , cross, crosstalk, etc.
(12). Setup
Unit & brightness & Auto-power off time can be set in this menu.
(11). Language set
Users can choose English or Chinese for operation.
W
IR
E
M
A
P
NF-8200-R
PAIR&L
NF-8200
NOYAFA
Setup
RJ11
RJ45
CALIBRATE
L C D N e t w o r k
L e n g t h Te s t e r
EMITTER
Anti-EI Wire Tracer
POWER
VOL
PUSH TO TEST
NF-8200-S
L C D N e t w o r k
L e n g t h Te s t e r
RECEIVER
Anti-EI Wire Tracer
Main tester (NF-8200)
Receiver (NF-8200-S)
Remote identifier (NF-8200-R)
Product interface and key introduction
Main unit port instructions
(1). Two RJ 45 interfaces on the main unit:
one of them is “MAIN” interface (“M” for short),
and the other is “SCAN” interface (“S” for short);
One RJ11 interface.
(2). M interface is used for measuring length and
others, but not for cable tracing; “S” interface is
used for cable tracing test and “local” connection test;
(3). RJ11 interface is used for line-to-line,
length testing and line tracing.
04
MAIN
RJ11
SCAN
Your excellent helper in cable test!
Your excellent helper in cable test!