Notice – Proheat M80 User Manual

Page 63

Advertising
background image

PROHEAT G-I PCM SERVICE MANUAL

4-32

If after changing the Temperature Sensor a diagnostic code is still

indicated, the G-I PCM is faulty. Go to G-I PCM replacement, page 4-41.

Test Procedure – Temperature Sensor measurement:

a)

Using a multimeter set for resistance, measure across pins A and B of

the sensor.

If the sensor measures out of range (see chart below), the sensor is

faulty. Go to Temperature Sensor replacement.

Figure 4-38: Temperature Sensor Test

RESISTANCE

TEMP

TEMP

(k-Ohms)

(°C)

(°F)

8574.14

-50

-58

5932.78

-45

-49

4155.34

-40

-40

2943.30

-35

-31

2108.75

-30

-22

1527.54

-25

-13

1117.67

-20

-4

826.12

-15

5

616.27

-10

14

463.88

-5

23

352.16

0

32

269.70

5

41

208.14

10

50

161.82

15

59

126.80

20

68

99.99

25

77

79.42

30

86

63.49

35

95

51.07

40

104

RESISTANCE

TEMP

TEMP

(k-Ohms)

(°C)

(°F)

41.31

45

113

33.62

50

122

27.52

55

131

22.63

60

140

18.71

65

149

15.55

70

158

12.98

75

167

10.89

80

176

9.17

85

185

7.75

90

194

6.59

95

203

5.62

100

212

4.81

105

221

4.13

110

230

3.56

115

239

3.08

120

248

2.68

125

257

NOTICE

If the resistance is below 1.363 k-Ohm

or above 10706 k-Ohm then there

will be a Code 7 and/or 9

Advertising
This manual is related to the following products: