I N S T R U C T I O N M A N U A L • M O D E L F M P O W E R S U P P LY
Constant energy mode with variable force triggering
Power Supply
Mode Codes
Program Version
Output Rating
SONICS AND MATERIALS
V3.0 845-73
1500W
FT EN NB IS 1 48 M
Trigger Force
Trigger (F) = 2%
Energy Set-Value
REF =
91.0 Ws
+ LIM = 0.20 sec
Upper Limit (Time)
Hold Timer
Timer 3
=
0.25 sec
– LIM = 0.10 sec
Lower Limit (Time)
Afterpulse Timer
Timer 4
=
0.00 sec
CAL PULSE = ON
Timer 5
=
0.25 sec
BOOSTER GAIN = 1.50
HORN NUMBER: 123
Pressure 30.00 Psig
0.17 sec
Actual Weld Cycle Duration
Assembly Number
100
91.2 Ws
Actual energy delivered
Percentage of available
65%P max
power used
P
100%
50%
0%
0
0.05
0.10
0.15
0.20
0.25 Sec
Idle Losses For Converter,
Booster and Horn