TeeJet 801 flowmeter User Manual

Installation

Advertising
background image

www.teejet.com

INSTALLATION

Please read before installing this equipment. Failure to do so may void your warranty.

Installation

The 801 flow meter gives the best accuracy when there is a smooth, unobstructed

flow through it. To minimize turbulance, there should be at least twelve inches of

straight plumbing upstream from the flow meter and at least 6 inches of straight

plumbing downstream from the flow meter. Mount the flow meter in a location that

physically protects it from damage and allows liquid to drain away after the sprayer is

flushed and secured at the end of the operating day. A straight, vertical section of the

main boom supply line is the ideal location for the flow meter.

Keep the flow meter from lying in a low section of the sprayer plumbing. This is

particularly important in cold weather when water might freeze in the flow meter and

cause damage to the unit. It is also important when applying chemical suspensions

which may settle out and stall the flow meter turbine if they cannot drain away.

Before installing the flow meter insert, make sure there are no obstructions in the

insert cavity. Clearance at the bottom of the cavity is very close and over tightening

or compressing of foreign material in the cavity can cause damage to the flow meter

body. Turn the insert in until it is hand tight.

Prior to each day’s spraying, the flow meter should be inspected to ensure there are

no leaks around the attachment fittings. At the end of the day, care should be taken

to thoroughly flush the flow meter with clean water.

Make sure no water or sediment is trapped in the flow meter

The impeller type flow meters supplied by TeeJet Technologies are inherently rugged.

However, continued use over time will eventually wear the internal bearings and

shafts until the meter becomes inaccurate. Replacement kits are available to repair

the flow meters. Contact your TeeJet Technologies dealer for these parts.

8 0 1 f L O w m e T e r

INSTALLATION, SpecIfIcATION, ANd wArrANTy INfOrmATION

8 0 1 F L O W M E T E R

TeeJet

TeeJet

O-RING

BOLT

HOSE

BARB

FLOW METER

SENSOR

MAIN

FLOW METER

BODY

FLANGED

CLAMP

Flow Meter

Insert

Main Flow

Meter Body

Flanged

Clamp

Bolt

O-Ring

Hose

Barb

Tee

Jet

>12 inches

> 6 inches

MAIN PRODUCT

PUMP

BYPASS LINE

AUTO RANGE

VALVE

R

PUMP DISCHARGE

FLOW METER

TO BOOMS

NOTE: The flow meter must be

mounted to that it will drain

completely when the sprayer

is not operating.

Bypass Line

Main Product

Pump

Pump Discharge

Flow Meter

>12 inches

Auto Range®

Valve

>6 inches

To Booms

NOTE: The Flow

Meter must be mounted

so that it will drain

completely when the

sprayer is not operating

Housing, Deutsch 3 Pos/Skts

Pin Out

Color

Function

A

Red

+12V

B

White

Signal

C

Black

Ground

Sensor

Advertising