Instrument Operation
The instrument is switched on by pressing the ON/OFF button located on the front of the
instrument. Within one second the thermometer is ready to work. Apply the tip of the probe to
the substance or medium to be measured. The instrument reading may take a few seconds to
stabilize, depending on the nature of the measurement.
MAX/MIN Memory Function
Press the MAX/MIN button to display the maximum reading and a MAX symbol will flash in the
display. Press the MAX/MIN button again to display the minimum reading and a MIN symbol will
flash in the display. Press MAX/MIN button again to return to the normal reading. To clear the
MAX/MIN temperature memory, press the MAX/MIN and ON/OFF buttons simultaneously.
Alarm Function
To operate the audible alarm function, simply press the set button to adjust the high or low
alarm reading, the alarm settings will then flash in the display. The user can adjust the alarm
temperatures via the up or down key, pressing the set key to retain the information. The audible
alarm will sound when the temperature setting has been exceeded and will cease once the
temperatures have returned to within the boundaries set.
Battery Replacement
Replace the batteries immediately if “Bat” illuminates or if the reading becomes erratic or the
display clarity fades, using two AAA, MN2400 or 1.5 volt equivalent. The batteries are located
under the battery cover at the rear of the instrument.
EMC/RFI
Readings may be affected if the unit is operated within a radio frequency electromagnetic field
strength of approximately 3 volts per metre, but the performance of the instrument will not be
permanently affected.
EcoTemp Specifications
Range
-58 to +392°F (-50 to +200°C)
Resolution
0.1°C or 0.1°F
Accuracy
±1.8°F (-58 to +302°F) ±1°C (-50 to +150°C)
Battery
AAA (2 x MN2400)
Battery Life
1,000 hours
Sensor Type
Thermistor
Display
Custom 22mm LCD
Dimensions
20 x 58 x 165mm
Weight
115 grams including probe
Product Warranty & Guarantee
This instrument carries a one-year warranty and guarantee against defects in either components
or workmanship. During this period, products that prove to be defective will, at the discretion of
ThermoWorks, be either repaired or replaced without charge.
The product warranty and guarantee does not cover damage caused by fair wear and tear,
abnormal storage conditions, incorrect use, accidental misuse, abuse, neglect, misapplication
or modification, or use with non-ThermoWorks hardware/software. No warranty of fitness
for a particular purpose is offered and the user assumes the entire risk of using the product.
Any liability by ThermoWorks is limited only to the replacement of defective materials or
workmanship, and ThermoWorks accepts no responsibility for consequential loss. In line with
our policy of continuous development, we reserve the right to amend our product specification
without prior notice.
EcoTemp Thermometer 810-960
Utah, USA
Ph: 801-756-7705 Fax: 801-756-8948
www.thermoworks.com
ecotemp pkg
3/23/04, 4:04 PM