Louisville Tin and Stove BFT201 User Manual
Page 14
BLOWER INSTRUCTIONS
INSTALLING THE VFB BLOWER (BFT201 / BFT202, BFT301 / BFT302 MODELS ONLY)
STEP 1. Remove blower assembly from shipping carton.
STEP 2. Insert blower assembly into upper back of heater (See Figure 11).
STEP 3. Secure blower to heater using three #8 screws (provided) through holes pre-punched in heater back.
STEP 4. Locate mounting holes for switchbox (See Figure 11).
STEP 5. Secure switchbox to heater using two #8 screws (provided).
STEP 6. Plug power cord into 115 volt three-prong grounded receptacle.
CAUTION:
Always unplug power cord before servicing or cleaning heater. This appliance is equipped with a three-
prong (grounding) plug for your rotection against shock hazard and should be plugged directly into a
properly grounded three prong receptacle.
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing.
FIGURE 11
Switchbox
Blower Assembly
Fan
Switch
Page 14
Blower Motor
White
(or ribbed)
Green
Black
WIRING DIAGRAM / VFB BLOWER
Power
Cord
If any of the original wire supplied with
the appliance must be replaced, it must
be replaced with a wire of at least a
105
º
C temperature rating.