Screwdriver

Fill Caps

4. Remove the six fill caps from the top of the

— battery with a screwdriver. Care should be

taken not to damage the fill caps. See figure 8.

FIGURE 8.

Large

Open irp ata

Filling

Adapter

•Hose

k

^1?

i

I ]

Upper Level

Marked on

Front of

Battery

FIGURE 9.

5. Lay acid package down, with “push in” facing

up. Using thumb, push in small perforated tab
at dot on front of package. Tear down large tab
to solid line, exposing hose. Do not use any
sharp object to open acid package.

6. Pull out hose from package and hold upright.

Squeeze hose forcing all acid back into
package. Cut off tip of hose and insert filling

—adapter. See figure 9.

7. Fill each cell to upper level marked on front of

battery. Replace fill caps on battery. See
figure 9.

8. Allow battery to sit for 20 to 30 minutes. Add

additional acid, if necessary, to bring it up to
the proper level.

^ WARNING I

Battery contains sulfuric acid. Refer to warning on
page 6. Antidote: EXTERNAL—Flush with water.
INTERNAL—Drink large quantities of water or

milk. Follow with milk of magnesia, beaten egg or

vegetable oil. Seek prompt medical attention.

EYES; Flush with cool water for at least 15
minutes, then seek immediate medical attention.

Since batteries produce explosive gases, keep all

lighted materials (cigarettes, lighters, matches,

etc.) away. Be sure to charge battery only in well-
ventilated areas.

KEEP BATTERIES

OUT OF THE REACH OF CHILDREN!