ВТН S E R V I C E H A N D B O O K
T R O U B L E S H O O T I N G
BLOWER (CONTINUED)
BTH 250, 962 & 966 SERIES ONLY
(Models equipped with blower speed reduction board)
STEP 8B
120 VAC TO BLOWER FROM SPEED REDUCTION BOARD
BTH 250, 962 & 966 Series oniy
Blower Speed Reduction Board
Go to control
board CN 5
Go to control
board CN 6
Go to control
board CN 2
STEP 8B: CHECK FOR 120 VAC TO BLOWER FROM CN2 PLUG PIN 1 AND 2 ON BLOWER
SPEED REDUCTION BOARD.
Condition:
• Reconnect all plugs to control board.
• On/Off switch is on.
• Call for heat is activated.
Insert meter probes into back of CN2 plug on pins 1 and 2 with CN2 plugged into blower speed
reduction board. Power should be on with a call for heat activated.
IF...
AND
THEN
120 VAC is not present
check CN2 plug connection, replace blower speed
reduction board if Step 8A has been performed and
results were successful.
120 VAC is present
blower is not running
check CN2 plug connection, replace the blower.
120 VAC is present
blower is running
continue to Step 8C.
STEP 8C: LISTEN FOR BLOWER TO REDUCE SPEED DURING IGNITOR WARM UP PERIOD.
IF...
THEN
blower runs, but does not reduce speed or stops during ignitor warm up period
replace blower speed reduction
board.
blower does reduce speed during ignitor warm up period
continue to Step 9A.