Dayton Operating Instructions and Parts Manual

5

®

Models 3E358B and 3E359B

Follow the mini-
mum fresh, outside

air ventilation requirements. If proper
fresh, outside air ventilation is not
provided, carbon monoxide poisoning
can occur. Provide proper fresh, outside
air ventilation before running heater.

FRESH AIR OPENING REQUIREMENTS

Square Feet

Heater Size

Opening

350,000 Btu/Hr

10.5

600,000 Btu/Hr

18.0

NOTE: If you use more than one heater,
provide extra fresh air. Provide a fresh
air opening of at least three square feet
for each 100,000 Btu/Hr rating.

VENTILATION

Review and
understand the

warnings in the General Safety Infor-
mation section. They are needed to
safely operate this heater. Follow all
local codes when using this heater.

TO START HEATER

1. Follow all ventilation and safety

information.

2. Locate heater to provide maximum

circulation of the heated air. Follow
all location requirements noted in
Safety Information, pages 3 and 4.

3. Fill fuel tank with Kerosene or No. 1

fuel oil.

4. Attach fuel cap.

Operation

5. Set thermostat dial to desired

temperature.

NOTE: Thermostat setting must be higher
than surrounding air temperature.

6. Plug power cord of heater into

three-prong, grounded extension
cord. Extension cord must be at least
six feet long.

Use only a three-
prong, grounded

extension cord. Use cord with proper
wire size to assure 120 volt operation.
See Extension Cord Wire Size Require-
ments below.

EXTENSION CORD WIRE SIZE
REQUIREMENTS

• 6 to 100 feet long, use 14 AWG

rated cord

• 101 to 200 feet long, use 12 AWG

rated cord

• 201 to 300 feet long, use 10 AWG

rated cord

• 301 to 400 feet long, use 8 AWG

rated cord

• 401 to 500 feet long, use 6 AWG

rated cord

7. Plug extension cord into standard

120 volt/60 hertz, three-hole,
grounded outlet.

FUELS

Use only kerosene,
or No. 1 fuel oil to

avoid risk of fire or explosion. Never
use gasoline, naphtha, paint thinners,
alcohol, or other highly flammable
fuels.

Do not use heavy fuels such as No. 2
fuel oil or No. 2 Diesel. Using heavy
fuels will result in:

• clogged fuel filter and nozzle

• carbon buildup on spark plug

• the need of nontoxic anti-icer in

fuel during very cold weather

IMPORTANT: Use a KEROSENE ONLY
container. Be sure storage container is
clean. Foreign matter such as rust, dirt,
or water will cause the flameout
control to shut down heater. Foreign
matter may also require you to clean
fuel system often.

General Safety Information

(Continued)