Figure 2-8: digital input pull-up resistor and, Termination circuit diagram – ADLINK PCIe-7200 User Manual

Page 30

Advertising
background image

Installation

21

2.8

Onboard Pull-ups and Terminations on the Digi-

tal Inputs

The PCI-7200, cPCI-7200 and PCIe-7200 have 32 digital input
channels. Onboard terminations for digital input circuits may be
needed for some applications. Schottky terminations can minimize
undershoot/overshoot disturbances caused by reflection noise on
high-speed bus lines. Table 2.1 lists the pull-ups and termination
status of PCI-7200, cPCI-7200, and PCIe-7200. Figure 2.8 is the
illustration of the pull-up resistor and terminations on-board.

Table 2-1: 7200 Series Termination

Figure 2-8: Digital Input Pull-up Resistor and Termination Circuit Diagram

Pull-up resistor

Terminations

PCI-7200 /
PCIe-7200

None

None

cPCI-7200

None

Schottky diode clamped to ground & power