Control location, Manual control, Installing the control – Bonaire / Celair (Tekelek) User Manual
Page 14: Ontrol, Ocation, Nstalling the

LP SERIES OWNER’S MANUAL
Controls Setup & Commissioning
TEK600 SERIES CONTROL
Page 14
C
ONTROL
L
OCATION
Manual Control
There is no thermostat in the manual wall control so it can be located anywhere that is
suitable to the customer. The control is supplied with a 20-metre connection loom to the
air conditioner.
Programmable Thermostat wall control:
•
Locate the wall switch on an internal wall of a conditioned room of the home,
approximately 1.5M above the floor level, in an easily accessible location as agreed
with the customer.
•
The controller must not be installed into areas where a ceiling register may blow cold
air over the control, or installed near appliances that may generate heat. This will
cause erratic thermostat operation.
•
The control is supplied with a 20-metre connection loom to the air conditioner.
The thermostatic wall-mounted controllers should be in a
conditioned room in a location that enables correct thermostat
operation. Ensure that the location is suitable for the customer.
I
NSTALLING THE
C
ONTROL
The wall controller is provided with a 20-metre loom to connect the wall control to the
control box in the unit.
Follow these instructions for best installation:
1. Connect the low voltage loom to one of the communication points in the unit control
box. Refer to wiring diagram
2. Pull the cable through to the designated point for the permanent application of the
wall control.
3. Mount the control base plate to the wall.
4. Connect the loom to the wall control and fit the control panel to the base plate.