Msi/plessey — continued, Msi/plessey data group characters – Datalogic Scanning QUICKSCAN QS6500BT User Manual

Page 234

Advertising
background image

Symbologies

6-146

QuickScan

®

QS6500/QS6500 BT

MSI/Plessey — continued

MSI/Plessey Data Group Characters

Once you’ve pre-set your desired Data Group Characters

1

using the

Data

Group Characters

feature found in

Chapter 5, Data Editing

, you can choose

to output up to two of those pre-sets whenever an MSI/Plessey bar code
is scanned.

To set this feature:

1. Determine which Data Group pre-set(s) to output. You can select

up to two from the following:

Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4

For example, your choice might be Data Group 2 only; Data
Groups 1 and 3; Data Groups 3 and 4; or no Data Groups.

2. Scan the START bar code to place the imager in Programming

Mode.

3. Scan the SET MSI/PLESSEY DATA GROUP CHARACTERS

bar code.

4. Turn to

Appendix B, Alpha-Numeric Pad

and scan the digits repre-

senting the Data Group designation(s) chosen in the first step
above. A digit of value zero (0) selects “no group.” For example,
scanning 3 and 0 would output only the character(s) set for Data
Group 3 whenever an MSI/Plessey bar code was scanned. Scan-
ning digits 1 and 2 would output both Data Groups 2 and 3. To
select no Data Groups at all, scan 0, then 0 again.

5. Scan the SET bar code to accept the digits scanned.

6. Scan the END bar code to exit Programming Mode.

1. In that chapter, you can select which character(s) and position(s) to place Data Characters

within scanned data output.

NOTE

The options in this section set Data Group Characters
for the MSI/Plessey symbology ONLY. If you wish to
enable this feature for additional symbologies, turn to
the options in the section specific to the other symbol-
ogy(s).