Fig 3, Through-the-ceiling installations – DuraVent Combustion Air Systems for DuraTech User Manual

Page 6

Advertising
background image

Fig 3

For Thru-the-Wall

installations using a

chase enclosure,

provide an access

door for cleaning.

Maintain at least 8"

clearance between

CAS Stove Pipe and

ceiling

6

THROUGH-THE-CEILING

INSTALLATIONS

Step 1. Determine the location of the CAS

Ceiling Support. The CAS Ceiling Support is

installed instead of a standard Support Box.

The CAS Ceiling Support can support up to

50-ft of DuraTech chimney or up to 70-ft of

chimney when the optional support straps are

used. The CAS Ceiling Support should be

located directly above the stove if possible to

facilitate the installation of the CAS Connector

Pipe. If possible, use a plumb bob to ensure

the center of the Ceiling Support will be directly

over the stove’s outlet. If the CAS Ceiling

Support is not aligned with the stove outlet,

elbows will be required for the offset.

Step 2. Install CAS Ceiling Support. Cut

and frame an opening for the CAS Ceiling

Support. Refer to Table 1 for proper framing

dimensions. Install the CAS Ceiling Support

into the framed opening, and ensure the

Ceiling Support is level. The square portion of

the Ceiling Support must be a minimum of 2”

below the finished ceiling (Fig 1, 2). Secure

the Ceiling Support with at least (2) 1-1/2”

wood screws per side; minimum of (8) wood

screws total.

For most installations, the CAS

Ceiling Support can be left at full height (does

not need to be cut down), and it can act as

an insulation shield for the attic space. If the

CAS Ceiling Support is being installed into a

cathedral ceiling, the box can often be installed

connected directly to the roof rafters, and then

folded over and nailed down or trimmed to be

flush with the roof (Fig 4).

Alternatively, the CAS Ceiling

Support can be installed in a chase enclosure

that is placed directly against the outside

of the Ceiling Support and extends up to

Figure 3

Figure 4

FOR THRU-

THE-WALL

INSTALLATIONS

USING A CHASE

ENCLOSURE,

PROVIDE AN

ACCESS DOOR

FOR CLEANING

MAINTAIN AT LEAST

8" CLEARANCE

BETWEEN CAS

STOVE PIPE AND

CEILING

CUT AND FOLD SIDES OF CEILING SUPPORT TO BE FLUSH WITH

ROOF. SECURE WITH NAILS OR SCREWS AS DESCRIBED.