Introduction – Glow-worm Clearly Heat Pump 5 kW User Manual
Page 8

0020111744_00 - 09/10 - Glow-worm
- 6 -
INTRODUCTION
16 Return heat pump temperature sensor
17 Water
fl ow rate sensor
18 Exchanger with plates
19 Hydraulic circuit venting valve
20 Plate to plate heat exchanger temperature sensor
21 Scroll
compressor
22 High pressure cooling circuit sensor
23 Liquid
reservoir
24 Compressor discharge temperature sensor
25 Filter
26 Pre-expansion temperature sensor
27 Electronic pressure regulator
A Heat
pump
fl ow
B
Heat pump return
2.5
Hydraulic and refrigerant schematic
1
26
25
27
24
2
3
4
5
6
20
21
22
23
19
17
16
14
15
13
12
11
10
9
8
7
18
Key
1
Temperature sensor for detecting end of defrosting
2 Filter
3 Ventilating
fan
4
Tubular heat exchanger
5
Exterior ambient sensor
6 Air/refrigerant
thermistor
7
4-way reverse cycle valve
8
Low-pressure circuit maintenance valve
9 Expansion
vessel
10 High-pressure circuit maintenance valve
11 Pump
12 Compressor suction temperature sensor
13 Air
trap
14 Suction
accumulator
15 Outgoing heat pump temperature sensor