3 evacuation of combustion gas, Diagram 3.2 – Glow-worm Ultrapower sxi User Manual
Page 12

12
3 Evacuation of Combustion Gas
Position
Position of the flue terminal
mm
Horizontal flues
A
directly below an opening, air brick,
opening windows
300
B
above an opening, air brick, opening windows
300
C
horizontally to an opening, air brick, opening
windows
300
D
below gutter, drain/soil pipe
25
E
below eaves
25
F
below a balcony or car port
25
G
from vertical drain pipes and soil pipes
25
H
from internal/external corners
25
H*
to a boundary alongside the terminal
300
I
above adjacent ground or balcony level
300
J*
from surface or a boundary facing the terminal
600
Position
Position of the flue terminal
mm
L
from opening (door/window) in car port
into dwelling
1200
M
vertical from a terminal
1500
N
horizontally from a terminal
300
Vertical flues
P
from another terminal
600
Q
above roof level
300
R
from adjacent opening window
1000
S
from adjacent wall to flue
300
(*) These dimensions comply with the building regulations,
but they may need to be increased to avoid wall staining and
nuisance from pluming depending on site conditions.
Diagram 3.2