Go Power! GPC-35-MAX/ User Manual

Page 6

Advertising
background image

GPC-35-MAX / 45-MAX / 55-MAX / 75-MAX / 100-MAX

___________________________________________________________

6

3.4 Reverse Polarity Fuses

The GPC is protected against reverse polarity on the DC output. If a battery or
the GPC is hooked up incorrectly, the fuses will blow and can be easily replaced.
Always use the same size and style fuse that came with the converter. To
change the fuses, use a screwdriver to loosen the screws and remove the fuses.
Always replace the fuses with the same type and rating. After inserting the new
fuses, tighten the screws firmly. DO NOT OVERTIGHTEN.


4.0 Charge Controller Options

4.1 GPC Charging

The optional GPC allows the GPC to operate as an automatic three-stage smart
charger giving the customer the benefit of a Bulk, Absorption, and Float stage
charging. The charging capacity of the GPC is increased, charge times are
decreased, proper and safe battery charging is ensured, and overcharging is
minimized. The GPC monitors the battery at all times. If the GPC voltage remains
in the float stage for more than seven days, the GPC automatically delivers a
boost charge as a 4

th

stage called equalize for a predetermined time, then

automatically returns to the normal float stage. The GPC series is recommended
for flooded lead acid and AGM batteries only.

Note: Check with your batteries manufacturer specifications to confirm the
GPC MAX charger will work.

4.1.1 Reduced Charge Times

The Bulk stage allows the batteries to be charged from the full rated load of the
battery. During this stage the batteries are recharged quickly to reduce charge
times.

4.1.2 Increased Battery Capacity

After the Bulk stage, the batteries are held in the Absorption stage for a
controlled period, ensuring a full and complete charge.

4.1.3 Reduced Battery Stress

During the Float stage, the GPC charge voltage is reduced. This minimizes
gassing while maintaining a full charge at the nominal rate of the battery.

4.1.4 Weekly Equalization for Longer Battery Life

If the batteries have not received a smart charge during a seven-day period, the
GPC initiates an equalization stage to top off the batteries, dissolving any sulfate
on the battery's internal plates and avoiding stratification.

Advertising
This manual is related to the following products: