0 installation instructions – Go Power! GP-PWM-25 User Manual

Page 9

Advertising
background image

Owner’s Manual | GP-PWM-25 Regulator

9

© 2010 Carmanah Technologies Corporation

Last revised: March 2010

5.0 Installation Instructions

1. Prepare for mounting. Use the template provided at the end of the manual to

mark the four mounting holes and the “cutting line for flush mounting.”

2. Complete the installation of the solar modules. If this GP-PWM-25 was

purchased as part of a Go Power! Solar Power Kit, follow the Installation Guide
provided. Otherwise follow manufacturer’s instructions for solar module mounting
and wiring.

3. Select wire type and gauge. If this GP-PWM-25 was purchased as part of a Go

Power! Solar Power Kit, appropriate wire type, gauge, and length is provided.
Please continue to Section 6, “Operating Instructions.” If the GP-PWM-25 was
purchased separately, follow the instructions included here.


Wire type is recommended to be a stranded copper UV resistant wire. Wire fatigue and
the likelihood of a loose connection are greatly reduced in stranded wire compared to
solid wire. Wire gauge should be able to sustain rated current as well as minimizing
voltage drop.

Suggested Minimum Wire Gauge
(Cable length 25 ft max. from solar array to battery bank)

50 Watt

#14 Wire Gauge

80 Watt

#12 Wire Gauge

95 Watt

#10 Wire Gauge

115 Watt

#10 Wire Gauge

160 Watt

#10 Wire Gauge

240 Watt

#10 Wire Gauge

Terminal Screw Torque

16 inch pounds (1.8N.m)

IMPORTANT: Identify the polarity (positive and negative) on the cable used for the
battery and solar module. Use colored wires or mark the wire ends with tags. Although
the GP-PWM-25 is protected, a reverse polarity contact may damage the unit.

Advertising