12 signal flow and lake processing – Lab.gruppen LM 44 User Manual
Page 18

12
Signal Flow and Lake Processing
Lake LM Series Quick Start and Field Reference Guide Rev 1.2.8
Figure 5-2: LM Series Signal Flow (Mesa Mode)
Please refer to section 6.10.4.2 of the LM Series Operation Manual for information on changing the Frame
configuration between Contour and Mesa Modes.
5.1.1
Level Adjustments & Mute Points
The numbers below correspond the points identified in Figure 5-1 and Figure 5-2.
Input Router Stage
- Input selection and MUTE
Input Mixer Stage
- Router ON/OFF connection to mixer and gain settings
Module Input Stage
- Mute (N/A for LM Series Mesa Mode) and gain settings
Module Output Stage
- Mute and gain settings
Output Router Stage
- Output ON/OFF routing connections
In Contour Mode, a Module can be connected to Input Routers 1-4 providing all five stages of mute/connec-
tivity functionality via the front panel interface or the Lake Controller; Input Routers 5-8 allow stage 1 input