页 11, Specification error message, Error message specification – SkyRC T6755 Charger User Manual

Page 11

Advertising
background image

SPECIFICATION

ERROR MESSAGE

AC Input

DC Input

Charge circuit power

Charge current range

Discharge current range

Current drain for balancing port

NiCd/NiMH battery cell count

LiPo/LiFe/Lilon cell count

Pb battery voltage

Net weight

Dimension

100-240V

11-18Volt

55W

0.1-7.0A

5W

0.1-2.0A

200mA/cell

1-15Cells

1-6Cells

2-20V

540g

140x165x60mm

Discharge current power

THE SET CONTAINS

1. SKYRC T6755 Charger

2. Multiple Balancing Board

3. 18AWG Wire Charging Cable

4. Power Cord

T6755

T6755

19

18

1

2

3

4

"

INT. TEMP TOO HIGH"

"EXT. TEMP TOO HIGH"

"DC IN TOO LOW"

"DC IN TOO HIGH"

"OVER TIME LIMIT"

"OVER CAPACITY LIMIT"

"REVERSE POLARITY"

"CONNECTION BREAK"

"CELL NUMBER ERROR"

"BALANCE CONNECTER ERROR"

"NO BATTERY"

"CONNECTION ERROR"

"BATTERY WAS FULL"

It incorporates a variety of functions for the systems to verify processes and the state of the
electronics. In case of an error the screen will display the cause of error and emit an audible
sound.

Incorrect polarity connected.

The battery is interrupted.

The Battery connection is wrong.

The cell number is wrong.

The internal temperature of the unit goes too high.

Input voltage less than 11V.

Input voltage higher than 18V.

The battery voltage is higher than the maximum
voltage which the user sets when charging in
balance mode.

The external temperature of the unit goes too high.

The battery capacity is more than the maximum
capacity which the user sets.

The charging time is longer than the maximum
charging time which the user sets.

The balance connect is wrong.

There is no battery connecting to the charger.

ERROR

MESSAGE

EXPLANATION

ERROR MESSAGE

SPECIFICATION

Advertising