6

SETUP AND CALIbRATION

NOTE: The RSD250 can be setup in the following ways:

On-board
The RSD250 can be setup by utilizing some components located on the printed circuit board. This allows access to
dancer arm sensor calibration and the adjustment of two tuning parameters. The is intended for less demanding ap-
plications where advanced tuning is not required.

RSD Communication Software
The RSD250 can be setup via the RSD Communications Software, an easy to use Windows based application that
can be downloaded from Nexen’s website. This allows for access to all setup, calibration and tuning parameters. Re-
fer to the RSD200 User Manual for instruction on downloading and making use for the Communications Software.

JUmPER SETTING

Jumper W2

Position 1, enables RDS Communications Software for setup

Position 2, enables on-board setup

PROvIDE POwER

Provide 120 or 240 VAC service to the RSD250 that
meets local electrical codes (See Electrical and Pneumatic
Connections section for connection information). After
providing VAC power turn RSD250 on with circuit breaker
disconnect switch (See Figure 2). Check the green LEDs,
I1 and I2, on RSD250 to make sure both are on.

CALIbRATE DPS60A

(For calibration via the Communications Software, refer to
the RSD200 User Manual)

After installing and connecting the DPS60A dancer arm
position sensor, the next step is to calibrate it.

On-Board Calibration

1. Place the dancer arm in the maximum storage posi-

tion.

2. Rotate the rotary switch on the RSD250 to position

E (See Figure 3). LED I7 will begin blinking; after
approximately ten seconds it will stay on for two
seconds, then turn off.

While the LED is blinking the dancer arm can
be moved; Once the LED is on continuously the
RSD250 will have captured the arm’s position.

3. Place the dancer arm in the minimum storage posi-

tion (See Figure 3).

Figure 3

Rotary

Switch

Jumper

I6
I5

Jumper

Indicator

12V

W4

10V
12V

W3

10V

R35
R38
R37

U4

R19

R20

DIG IN 2

W6

TX

DIG IN 1

W5

RX

I2

I7

I1

1

W2

2

I OUT

W7

V OUT

4. Rotate the rotary switch on the RSD250 to position

F (See Figure 3). LED I7 will begin blinking; after
approximately ten seconds it will stay on for two sec-
onds, then turn off.

While the LED is blinking the dancer arm can
be moved; Once the LED is on continuously the
RSD250 will have captured the arm’s position.