Power measurement, Power measurement –70 – Altera Arria V GT FPGA Development Board User Manual

Page 80

Advertising
background image

2–70

Chapter 2: Board Components

Power Supply

Arria V GT FPGA Development Board

December 2014

Altera Corporation

Reference Manual

Power Measurement

There are 16 power supply rails that have on-board voltage, current, and wattage
sense capabilities using 24-bit differential ADC devices. Precision sense resistors split
the ADC devices and rails from the primary supply plane for the ADC to measure
voltage and current. A SPI bus connects these ADC devices to the MAX II CPLD
EPM2210 System Controller as well as the Arria V GT FPGA.

Figure 2–13

shows the block diagram for the power measurement circuitry.

Table 2–36

lists the targeted rails. The schematic signal name column specifies the

name of the rail being measured while the device pin column specifies the devices
attached to the rail. If no subnet is named, the power is the total output power for that
voltage.

Figure 2–13. Power Measurement Circuit

SCK

DSI

DSO

CSn

8 Ch.

Power Supply Load #0-14

R

SENSE

SCK

DSI

DSO

CSn

8 Ch.

EPM2210

Arria V

FPGA

LTC2418

To User PC

Power GUI

JTAG Chain

Feedback

14-pin

2x16 LCD

E
RW

RS
D(0:7)

Supply

#0-14

EPM570

USB
PHY

Embedded

USB-Blaster

Table 2–36. Power Measurement Rails (Part 1 of 3)

Switch

Schematic Signal Name

GUI Name

Voltage

Device Pin

Description

1

A5A_VCCR_VCCL_GXB

A5A_XCVR_GXB

1.2V

VCCR_GXB,
VCCL_GXB

XCVR analog receive and clock
network

A5A_VCCT_GXB

1.2V

VCCT_GXB

XCVR transmitter power

2

A5A_VCCA_2.5V

A5A_VCCA

2.5V

VCCA_FPLL

PLL analog power

2.5V

VCC_AUX,
VCCA_GXB

Auxiliary

Advertising