2.4

Watchdog Timer Setting

The watchdog timer makes the systems auto-reset while it stop to work for
a period. The onboard watchdog timer can be set as system reset or active
NMI mode by jumper JWDT; the timeout value can be set as 1, 2, 10, 20,
110, or 220 seconds by jumper SWDT.


Jumper: JWDT
Type: onboard 3-pin header

JWDT Watchdog

Timer

1-2 Active

NMI

2-3

Reset

Default setting

SWDT

1

JWDT


1

4












Jumper: SWDT
Type: onboard 4-button / 2-level DIP switch

Timeout

Value

SWDT

1 2 3 4

1 Second

OFF

OFF

ON

OFF

2 Seconds

OFF

OFF

ON

ON

10 Seconds

OFF

ON

OFF

OFF

20

Seconds

OFF ON OFF ON

110 Seconds

ON

OFF

OFF

OFF

220

Seconds

ON OFF OFF ON

Default setting