Dc characteristics – Zilog eZ80F92 User Manual

Page 47

Advertising
background image

eZ80F92 Development Kit

User Manual

UM013911-0607

DC Characteristics

43

DC Characteristics

Understanding proper DC current requirements for the eZ80Acclaim!

®

Development Platform when application modules are plugged into it is
very important for developing applications. This section provides an esti-
mate of the average current requirement when different combinations of
these application modules are plugged in to the eZ80Acclaim!

®

Develop-

ment Platform.

The receiver supply current is 90–150 µA and the transmitter supply cur-
rent is 260 mA when the LED is active. The measurements of current that
are shown in Table 26 are for the user’s reference. These values can vary
depending on the type of application that is developed to run with the
platform.

Table 26. DC Current Characteristics of the

eZ80Acclaim!

®

Development Platform with Different Module Loads

Platform/Modules Configurations

Current

Requirement (mA) Status

eZ80Acclaim!

®

Development Platform

and eZ80F92 Flash Module

173

When connected only to a
power supply, and when
no program is running.

eZ80Acclaim!

®

Development Platform,

eZ80F92 Flash Module, and Modem
Module

174

When connected only to a
power supply, and when
no program is running.

eZ80Acclaim!

®

Development Platform,

eZ80F92 Flash Module, and
Thermostat Application Module

195

When connected only to a
power supply, and when
no program is running.

eZ80Acclaim!

®

Development Platform,

eZ80F92 Flash Module, Modem
Module, and Thermostat Application
Module

203

When connected only to a
power supply, and when
no program is running.

Advertising