1 sw1 switch setup – AMETEK DCS-E 1kW Series Programming Manual User Manual

Page 14

Advertising
background image

Isolated Analog Programmer Operation

DLM-E Series and DCS-E Series

2.1.1

SW1 Switch Setup

The following sections describe the functions of the various switch positions:

Voltage Programming Range Select (V PROG): SW1-1, ON (1) position, selects 0-5VDC
programming range for the output voltage. Must also be set to ON (1) position when the Isolated
Analog Programmer is wired for 4-20mA input programming. OFF (0) position, selects 0-
10VDC programming for the output voltage.

Current Programming Range Select (I PROG): SW1-2, ON (1) position selects 0-5VDC
programming range for the output current. Must also be set to ON (1) position when the Isolated
Analog Programmer is wired for 4-20mA input programming. OFF (0) position, selects 0-10VDC
programming for the output voltage.

OVP Programming Range Select (OVP PROG): SW1-3, ON (1) position selects 0-5VDC
programming of OVP threshold. OFF (0) position, selects 0-10VDC programming for OVP
threshold.

Output Voltage Monitor Range Select (V MON): SW1-4, ON (1) position selects 0-10VDC
range for readback of output voltage. OFF (0) position selects 0-5VDC readback of output
voltage. 4-20mA readback for output voltage is independent of the position of this switch.

Output Current Monitor Range Select (I MON): SW1-5, ON (1) position selects 0-10VDC
range for readback of output current. OFF (0) position selects 0-5VDC readback of output
current. 4-20mA readback for output current is independent of the position of this switch.

Remote ON-OFF Level Select (S/D): SW1-6, ON (1) position selects ACTIVE-HIGH logic level
for disabling the output with the S/D signal of the Isolated Analog Programmer connector. OFF
(0) position selects the ACTIVE-LOW logic level for disabling the output with the S/D signal of
the Isolated Analog connector.

Figure 2–1. Rear Panel View, DLM-E Series 3kW and 4kW Power Supply

Figure 2–2. Rear Panel View, DCS-E Series 1kW Power Supply

2-2

M51A Option

Advertising