Monitor Setting Display
In monitor mode, in order to change the monitor status, the users can press UP or DOWN arrow key or
change parameter P0-02 directly to specify the monitor status. When the power is applied, the monitor
status depends on the setting value of P0-02. For example, if the setting value of P0-02 is 2 when the
power is applied, the monitor function will be “Pulse counts of pulse command”, the C.P monitor codes
will first display and then the pulse number will display after.
P0-02
Setting
Display Message
Description
Unit
0
Motor feedback pulse number
pulse
1
Motor feedback rotation number
rev
2
Pulse counts of pulse command
pulse
3
Rotation number of pulse command
rev
4
Position error counts
pulse
5
Input frequency of pulse command
kHz
6
Motor rotation speed
rpm
7
Speed input command
volt
8
Speed input command
rpm
9
Torque input command
volt
10
Torque input command
Nt-m
11
Average load
%
12
Peak load
%
13
Main circuit voltage
volt