20. SETUP

MENU

Press [MENU]. The MENU indicator will turn on.
The display will show the following parameters with their current settings.

Turn the wheel to select a menu option.
Press the {CHANGE} softkey to modify the current setting, then press {BACK} after making
selection.

Press the {EXIT} softkey to exit the Setup Menu.


PARAMETER DESCRIPTION

LOUTH

(PER/VTR)

Enter the controlled channel’s Louth port number (1 - 9) on the numeric keypad. Then press
the {INPUT} or {OUTPUT} softkey. An INPUT is indicated by ‘-‘ before the port number.

To CREATE (RECORD) clips, an INPUT channel must be selected.
To playout CLIPS, an OUTPUT channel must be selected.

Enter ‘0’, to turn off the port.

PROTOCOL

(PER/VTR)

{LOUTH} or {BVW}.

STANDARD

{NTSC} or {DF} or {PAL}

WIND MODE

{HOLD}
(Fast wind is maintained only while key is depressed.)
OR
{LATCH}
(Fast wind is initiated and maintained with momentary key press.)
{SPEED}
Press the softkey to change the speed setting (3.9, 6.0, 8.1, 10.0, 23.7).

EXTENDED IDs

{ON} – Allow up to 32-character CLIP IDs.
{OFF} – Allow up to 8-character CLIP IDs.

RECORD MODE

(PER/VTR)

Press a softkey to select the desired record mode: Lockout or Crash.

Advertising