1.

INSTALLATION & CONFIGURATION

INSTALLATION

Refer to the REAR PANEL CONNECTORS section for power, Ethernet, and switch information.

Use the Remote Device Assignment web page to configure connectivity to GTP-32 Control
Processor or DC20 Device Controller.

Use the Event Action Table web page to send USP key presses to Remote Devices defined on
the Remote Devices Assignment web page.

Use the Tally Assignment web page to configure key tallies- text and color.


POWER

The USP-RDC is powered from a DNF supplied external power supply.

DEFAULT ETHERNET CONFIGURATION

IP Address: 192.168.10.217

Subnet Mask: 255.255.255.0

Gateway: 192.168.10.1


RESET

Press the RESET switch on the rear of the unit to reboot it.


Switch S1

Press and hold the S1 switch for 10 seconds to reset the IP address, subnet mask, Gateway, and
configuration to factory defaults.


CONFIGURATION

The USP-RDC is configured using a standard web browser (Internet Explorer, Firefox, and
Chrome). Enter the USP’s IP address in the Address/ URL bar, typically located at the top of the
web browser page, to access the configuration Home Page. Use the links on the left side of the
Home Page to access the desired configuration web page.

All configuration settings are saved in non-volatile memory in the unit. Settings are retained
when power is removed.

Settings may be uploaded to a computer as a configuration file (.dnf) for storage. Configuration
files may be downloaded from a computer into the USP to restore a saved configuration. A
configuration file contains all of configuration settings except IP address, subnet mask, and
gateway address. Partial configuration upload or download is not supported. The configuration
file is a not a text formatted file. It can not be viewed or modified with a text editor.

To access the System Configuration web page, use the following log-on when prompted.

User name: dnfuser

Password: controls

NOTE- Redundant Mode of operation is enabled at powerup.