27

© 2 0 0 4 D i r e c t e d E l e c t r o n i c s , I n c .

C

Co

on

nttrro

oll M

Mo

od

du

ulle

e P

Prro

og

grra

am

mm

miin

ng

g

Depending on the vehicle, use the following data with the

instructions to program your system. These wire loops are found

at the side of the control module.

D

Diieesseell M

Mood

dee ((B

BL

LU

UE

E)) - Cut this loop if you have a diesel vehicle.

When cut the remote start will start the engine about 30 seconds

after pressing the

button twice.

Uncut – Gas Mode

Cut – Diesel Mode

V

Voollttaaggee M

Mood

dee//T

Taacch

hoom

meetteerr M

Mood

dee - Default is voltage mode. The

control module will automatically look at the tachometer input

during normal driving. If it finds a valid tachometer signal the

module will use tachometer mode, otherwise the module will use

voltage mode (battery voltage will rise after the engine starts).

To program tachometer mode, start the engine and let it run for

at least 30 seconds. If the tachometer is seen by the control

module, it will enter tachometer mode, and will monitor the

tachometer input for the next startup.

The system is programmed to attempt two starts using

tachometer mode. If after the second start attempt the control

module did not see a tachometer input the system will attempt

to start a third time using voltage mode.