Description and connection
The heating mat consists of a heating cable attached to supporting aluminium foil.
Heating cables are connected to the 230V, 50Hz network. Rating IP 67. The connection may only
be carried out by persons with relevant electrici
an’s qualifications (according to ordinance 50/78
Coll. in the Czech Republic)
Insulated conductors (milky colour) are active
– connect them to the phase and neutral conductor.
Connect the free shielding wires to the green-yellow protective conductor.
Installation
Before carrying out the installation, make a drawing of the placement of the heating mat according
to the floor plan of the room.
Clean dirt from the floor.
Lay impact insulation according to the instructions of the manufacturer.
Carry out the laying of the heating mat according to the placement plan. After adapting the mat, the
heating conductor must always be attached with connecting tape, which simultaneously creates a
conductive connection to the aluminium foil. Minimum distance from the walls is 50mm.
In places where the mat is not installed in the ground plan, the surface needs to be levelled with a
levelling layer (e.g. 2mm thick Mirelon).
Make a groove in the base for the supply lead (cold lead) of the mat. The supply conductor must not
touch or cross the heating cable.
Create a groove in the base for the installation of the floor sensor. The groove must run between the
loops of the heating mat.
Install the floor sensor of the thermostat. The sensor is to be placed into an installation tube
(“gooseneck”); it mustn´t cross or touch the heating cable.
6) Laminate floating floor
7) Al-mat heating mat
8) Impact insulation of the floating floor
9) Installation tube with the floor probe
10) Concrete layer
1
2
3
4
5