Fenix THERM 350 User Manual

Page 9

Advertising
background image

If the thermostat is set as a floor thermostat (F), it displays the current tem-

perature in the floor.

If the thermostat is set as a room thermostat (R), it displays the current

temperature in the room.

If the thermostat is set as a room and floor thermostat, (R&F) it displays the

current temperature in the room.

Frost protection programme

This programme is designed for long absence. When this program is selec-

ted, the thermostat will regulate by this set value. All other set values and

settings will remain in memory and the thermostat will go back to them

when this program will be deactivated. The temperature can be between 5

°

C

and 15

°

C. Factory set temperature is 10°C.

1. Press

.

The display shows

.

2. Press

repeatedly until the display shows

.

Press

.

3. Press

repeatedly until the display shows

repeatedly until the display shows

.

Press

.

4. Now the selected temperature is flashing.

5. Press

or

to select the set value. Confirm with

•.

To activate this programme:

1. Press

.

The display shows

.

2. Press

repeatedly until the display shows

.

Press

.

One of the icons for preset programmes will flash, depending on the current

setting. (If no icon flashes, no preset programme is selected).

3. Press

to select

. Confirm with

.

If a preset programme is selected the programme starts up.

is shown

together with

and indicates that the programme is running.

Display contrast

1. Press

.

The display shows

.

2. Press

.

The display shows 1,2, 3.......8 depending on actual setting.

3. Press

or

,

to change the contrast. Confirm with

.

Adaptive function

The thermostat is equipped with a so-called adaptive function, which means

that if you have programmed the thermostat to keep a certain temperature

at a certain time, the thermostat will calculate itself when to start heating

so that the floor surface will keep the set temperature at the preset time.

Factory set is ON.

To deactivate the adaptive function:

1. Press

•.

The display shows

.

2

.

Press

repeatedly until the display shows

.

Press

•.

3

.

Press

repeatedly until the display shows “AF”. Press

Press

.

4. The display shows the actual settings. Press

Press

to change. Confirm with

.

Operation time

The thermostat can show the operation time in percent for the last 24 hours,

7 days, 30 days or 365 days. To see the percentage operation time:
1. Press

.

The display shows

.

2. Press

repeatedly until the display shows

. Press

.

The display shows operation time in percent for the last 24 hours.

3. Press

. The display shows and operation time in percent for the last

7 days.

4. Repeat the steps above to show the operation time for the last 30 days or

365 days, respectively.

Ventilation mode

If the measured temperature is reduced by more than 3°C during one minu-

te, the thermostat is automatically put in ventilation mode. The thermostat

stops heating for 15 minutes. When 15 minutes have passed, the thermostat

returns to normal mode.

The ventilation mode is always active, regardless of which programme is
running.

Troubleshooting

When an error occurs, the thermostat will switch off the heating. The LED

flashes alternately in red and green. The LCD-display shows a flashing error

code, the display shows according to below:

Error 1: Short circuit room sensor.

Error 2: Interruption room sensor.

Error 3: Short circuit floor sensor.

Error 4: Interruption floor sensor.

The supply cord of this control can be replaced only by the manufacturer or

his accredited service agent.

Technical specifications

Voltage

230 VAC-50 Hz

Air temperature range

5-37

º

C

Floor temperature range

5-37

º

C

Temperatur limiter

5-45

º

C

Breaking capacity

3600W / 16A / 230 VAC

Connection cable

max 2,5 mm

2

Load

cos

φ

= 0,3

Hysteresis

+- 0,3

º

C

Protection class

IP21

Run reserve

36 hours

Colour

Polar white as standard, aluminium

and bronze as option

Background lighting

Shines 30 seconds after the last

button is pushed

Max length sensor cable

45 m, 2 x 1,5mm

2

The LED’s indication:
Green

230 VAC supply connected

Red

Floor heating cable operating

Flashing green and red light

Error indication

Adapted for Eljo Trend, Elko RS, Strömfors and Merten frame-systems.
EMC-certified and can handle an overvoltage of 2 500 VAC.
Safety standard: CE
Fulfils the RoHS and WEEE-directive

FENIX Therm 350 with accessories

Article

Dimensions (mm)

FENIX Therm 350

81x81x40

Extension frame

81x81x18

Sensor cable 3 m (included in the pack)
Back plate, polar white

86x86x6

Model no. 66 210 84
Type IB
Degree of pollution 2
Rated impulse voltage = 4000V
Size of terminal 2,5 mm

2

Installation instructions FENIX Therm 350 English Page 3/3, 071217

Start / Stop set back programme

This will not erase settings, will only start and stop set back
programme.

Start programme:
1. Press

. Display shows

.

2. Press

repeatedly until display shows

. Press

.

If a programme is active one icon is flashing

,

,

,

.

3. Press

or

repeatedly to choose icon, chosen icon must

flash. Confirm with

.

Stop programme:
1. Press

. Display shows

.

2. Press

repeatedly until display shows

. Press

.

If a programme is active one icon is flashing

,

,

,

.

3. Press

or

repeatedly until no icon flash. Confirm with

.