TWIN SCREW PUMPS. ORIGINAL USER INSTRUCTIONS. ENGLISH. 71569243 – 07/10

Page 30 of 53

®

Care must be taken when adjusting the gland

on an operating pump. Safety gloves are essential.
Loose clothing must not be worn to avoid being
caught up by the pump shaft. Shaft guards must be
replaced after the gland adjustment is complete.

Never run gland packing dry, even for

a short time.

5.9.3 Pumps fitted with mechanical seal
Mechanical seals require no adjustment. Any slight
initial leakage will stop when the seal is run in.

Before pumping dirty liquids it is advisable, if
possible, to run in the pump mechanical seal using
clean liquid to safeguard the seal face.

External flush or quench should be

started before the pump is run and allowed to flow for
a period after the pump has stopped.

Never run a mechanical seal dry,

even for a short time.

5.9.4 Bearings

If the pumps are working in a potentially

explosive atmosphere temperature or vibration
monitoring at the bearings is recommended

If bearing temperatures are to be monitored it is
essential that a benchmark temperature is recorded
at the commissioning stage and after the bearing
temperature has stabilized. Record the bearing
temperature (t) and the ambient temperature (ta).
Estimate the likely maximum ambient temperature
(tb). Set the alarm at (t+tb-ta+5)

°C [(t+tb-ta+10)°F]

and the trip at 100

°C (212 °F) for oil lubrication.



5.9.5 Normal vibration levels, alarm and trip
For guidance, pumps generally fall under a
classification for rigid support machines within the
International rotating machinery standards and the
recommended maximum levels below are based on
those standards.

Alarm and trip values for installed

pumps should be based on the actual measurements
(N) taken on the pump in the fully commissioned as
new condition. Measuring vibration at regular
intervals will then show any deterioration in pump or
system operating conditions.

Vibration velocity – unfiltered

mm/s (in./s) r.m.s.

Twin Screw

Normal N

≤ 7.6 (0.30)

Alarm N x 1.25

≤ 8.9 (0.35)

Shutdown trip N x 2.0

≤ 11.2 (0.44)


5.9.6 Stop/start frequency
Pump sets are normally suitable for the number of
equally spaced stop/starts per hour shown in the
table below. Check actual capability of the driver and
control/starting system before commissioning.

Motor rating kW (hp)

Maximum stop/starts

per hour

Up to 15 (20)

15

Between 15 (20) and 90 (120)

10

Above 90 (120)

6


Where duty and standby pumps are installed it is
recommended that they are run alternately every
week.

5.10 Stopping and shutdown


5.10.1 Short term

a)

Never close the outlet valve prior

to stopping the pump. Stop the driver.

b) Leave open the valve supplying auxiliary sealing

fluid to maintain prime while the pump is idle.

c) On pumps with steam jacketed bodies and/or

stuffing boxes, maintain steam flow to prevent
pumping liquid from setting up in the internals of
the pump.


5.10.2 Long term

a)

Never close the outlet valve prior

to stopping the pump. Stop the driver.

b) Switch off flushing and/or cooling/heating liquid

supplies at a time appropriate to the process.

c) On pump with steam jackets, shut off steam flow

and allow pump to cool.

d)

For prolonged shut-downs and

especially when ambient temperatures are likely
to drop below freezing point, the pump and any
cooling and flushing arrangements must be
drained or otherwise protected. Refer to section
2.4.2 Long-term

storage.