Flowserve PSS II User Manual
Page 5
2.4
Gland Split
Joint
Gasket
Position
The gland
split joint
gaskets
must be
positioned
as shown in
Figure 5. If
they are not,
Split Joint
Gasket
Gland
Seat Gasket
Gland Gasket
Figure 5
5
2.5
Gasket Chamfers - The seat gasket, rotating face gasket, and
sleeve gasket are all chamfered on one side and must be
positioned as shown in Figure 6.
Figure 6
Rotating Face
Gasket
Chamfer Side
Seal Drive
Sleeve Gasket
Chamfer Side
Gland
Split Joint Gasket
Split
Joint
Gasket
Seat Gasket
Chamfer Side
2.3
Seal Drive Split
Joint Gasket
Position
The split joint
gaskets should be
positioned flush
with the groove
surfaces indicated
in Figure 4. The
gasket end should
be flush to 0.030
inch (0.76 mm)
shorter than the
groove as shown.
Flush
Flush
Flush
Split Joint Gasket
Figure 4
0.030"
0.000"
(0.76 -
0.00 mm)
reposition them as needed.