9 tables, Nordstrom valves, Torque values for pressure retaining bolting – Flowserve Nordstrom Dynamic Balance Plug Valve and Double DB Plug Valve User Manual
Page 30: Flow control
![background image](/files/784567/content/doc030.png)
Flow Control
Nordstrom Valves
30
Dynamic Balance
®
Plug Valve and Double DB
®
Double Isolation Plug Valve
FCD NVENIM2005-01
9 Tables
Torque Values for Pressure Retaining Bolting
Table 1– Size 4 and Smaller Valve Gland Bolting
Bolt Size
1st
Torque (ft-lb)
2nd
3rd
3
⁄
8
- 16 UNC
Hand Snug
15
25
1/2 - 13 UNC
Hand Snug
40
55
5
⁄
8
- 11 UNC
Hand Snug
80
110
Table 2 – Size 4 and Smaller Valve Cover Bolting
Bolt Size
Torque (ft-lb)
1st
2nd
3rd
3
⁄
8
– 11 UNC
20
85
110
3/4 – 10 UNC
20
135
180
7
⁄
8
– 9 UNC
30
220
290
1 – 8 UNC
45
340
450
1
1
⁄
8
– 8 UNC
70
530
705
11/4 – 8 UNC
90
675
900
Table 3 – Size 6 and Larger Valve Pressure Retaining Bolting
(all parts)
Thread Size
Torque (ft-lb)
Minimum
Maximum
1/4 – 20
5
6
5
⁄
16
- 18
10
12
3
⁄
8
– 16
15
18
7
⁄
16
– 14
25
30
1/2 – 13
38
45
9
⁄
16
– 12
58
68
5
⁄
8
– 11
76
90
3/4 – 10
127
150
7
⁄
8
– 9
205
240
1 – 8
315
370
1
1
⁄
8
– 8
500
585
11/4 – 8
640
750
1
3
⁄
8
– 8
870
1020
11/2 – 8
1010
1200
1
5
⁄
8
– 8
1400
1650
13/4 – 8
1900
2250
1
7
⁄
8
– 8
2550
3000
2 – 8
2800
3300
21/4 – 8
4000
4900
21/2 – 8
5500
5800
23/4 – 8
7400
9100