Gasboy 9152AX User Manual
Gasboy Hardware
031673 04/16/01
INSTRUCTIONS FOR REPAIRING
067026 SOLENOID VALVE W/STEEL INSERT
MODELS: 9152AX, 9152AXTW1, 9152AXTW2
A small amount of ¾” flanged solenoid valves were supplied to Gasboy with steel inserts in the inlet bolt holes.
With force on the discharge piping, the inserts may slide out of the valve causing a leak between the valve and the
flange. These valves (P/N 067026) were used in some shipments of Gasboy commercial dispensers (Models
9152AX, 9152AXTW1 and 9152AXTW2).
Before or during installation and startup of the
dispensers, a qualified repair technician should check
the valve. The technician should inspect the valve where
the bolts protrude through the back side of the brass inlet
flange. If the area immediately surrounding the bolts is
brass, there is no problem. If there is a steel ring (steel
insert) immediately surrounding the bolt (it may be
recessed), the bolts must be replaced to avoid a
potential leak.
This Gasboy repair kit, P/N 032140, will remedy the
problem. It contains the following:
Item
Part No.
Description
Qty
1
051925
5/16-18 x 1-1/4” long Hex Head Bolt
2
2
068875
5/16 Lockwasher
2
3
068080
5/16 Washer
2
4
038605
5/16-18 Locknut
2
5
031673
Instructions (this sheet)
1
Refer to the Installation/Operation Manual supplied with your dispenser for all applicable Warnings and
Safeguards before proceeding with any repairs
If you have determined that your dispenser requires this valve repair kit, you
should perform the following:
1. Disconnect all power to your dispenser and block the island to prevent
unauthorized access.
2. Remove and discard the existing bolts that thread into the steel inserts.
3. Install the 1-1/4” long bolt (item 1) with the lockwasher (item 2) and
tighten securely.
4. Install the washer (item 3) and locknut (item 4) and tighten securely.
5. Reapply power to the dispenser and inspect for leaks.