Reset button
G&D Dynamic-UserCenter 32 · 11
Reset button
The Reset button is placed between the Identification LED and the RS 485 interface on
the device’s front panel.
The button allows you to reset the default settings and disable the netfilter rules.
Resetting the default settings
Pressing and holding the button during the booting process resets the device’s
default settings.
How to reset the default settings of the central module:
1. Turn off both power packs of the central module.
2. Press and hold the Reset button on the front panel of the device.
3. Keep the button pressed and turn the device on.
4. Release the button when the green Switch LED starts blinking.
NOTE:
To prevent you from pressing the button by accident, you need to use a
thin, pointed object to press the button.
NOTE:
After the function has been carried out, the device’s default settings apply
again. However, the configured assignment of the Dynamic Ports remains unal-
tered.
NOTE:
You can also reset the default settings in the Config Panel web application.