3 default values of the ip user module, Create the delivery status via the ip user module, Default values of the ip user module – Guntermann & Drunck UCON-IP-NEO Web Interface User Manual
Page 39
Guntermann & Drunck GmbH
UCON-IP-NEO Web interface
Page
39
3.2.4.2 Create the delivery status via the IP user module
The creation of the delivery status can also be executed through the device.
There is a small button on the front, which can be pushed with a pointed object.
This button activates the
Set system defaults. For this, proceed as follows:
Turn
off
the IP user module
Press and hold the button
Turn
on
IP user module
Wait until the status LED flashes rapidly.
Release the button.
The IP user module is set to the delivery status. The rapid flashing stops after
several seconds. The device will now start.
3.2.4.3 Default values of the IP user module
This chapter shows the factory settings of IP user module in form of a table:
Login name:
Admin
Password: 4658
Menu
Section
Line
Default value
Configuration Server
IP
assignment
Static
IP
address
192.168.0.1
Net
mask
255.255.255.0
Connection
type
Auto
Assignment of global
settings
Static
Host
name
EcoV3
system
User
name
Admin
Timeout
WebIF
30
Standard
language
German
Access
Java-Client
Activated
Timeout
client
10
TCP
port
27998
Issue date/ time
manually
time
zone
Berlin
Syslog
Local
syslog
Deactivated
Log
Level
Info