X-y command thc, 6 specifications & unit mounting, Product configuration manual x-y lifter assembly – Hypertherm THC X-Y Table Product Configuration User Manual
Page 9
1-6
SPECIFICATIONS & UNIT MOUNTING
X-Y Command THC
Product Configuration Manual
X-Y Lifter Assembly
Electrical
Motor ..................................................................+ 2.48 VDC, 2- phase (3.3 amp per ph.)
Limit switches ......................................................+ 24 VDC
Lifter Control Function
Motor ................................................................Stepper
Motor Drive ........................................................Stepper, chopped constant current
Lifter Feedback ..................................................Encoder
Lifter Limit Switches ..........................................Home switch and lower limit switch
Maximum Z Axis Speed......................................200 inches (508 cm) per minute
Maximum Z Axis Stroke......................................8- inches (203 mm)
Weight and Dimensions....................................Figure 1-4
Figure 1-4 X-Y Lifter Assembly Weight and Dimensions
THC
.66a
21.8"
(554 mm)
2.8"
(71 mm)
5"
(127 mm)
18 lb
(8.2 kg)
4.67"
119 mm
5.78"
164 mm
4