background image

Door Type Series DOC COM 1.0 06

www.insingermachine.com 800-344-4802

Insinger dishmachines are user-friendly, making

them the easiest dishmachines on the market to

operate and maintain.
By following these operating procedures your

Insinger dishwasher will give you years of trouble

free service.
OPERATION INSTRUCTIONS

1. Ensure drain overflow tube is in place. Close all

tank drain valves. One drain is provided for
each tank of the dishmachine.

2. Check for proper installation and cleanliness of

all internal, removable components such as
suction strainers, scrap screens, and spray
manifolds.

3. Ensure all water & steam lines are open.

Ensure electrical circuits are on.

4. Close machine doors.

5. Move the power toggle switch to the ON posi-

tion. The machine will fill the tank, run through a
complete wash/rinse cycle and shut-off.

6. When the tanks are full the tank heat will oper-

ate automatically. Proper wash tank tempera-
ture is 156ºF minimum. Proper final rinse tem-
perature is 180

º

F minimum at 20 PSI, while in

the final rinse cycle.

CAUTION:

To ensure proper operation

of the auto tank fill feature and the tank heaters,

the tank level floats MUST be cleaned daily.

CAUTION:

Overloading racks will minimize the

proper cleaning of ware.

7. Open doors.

8. Insert a rack of soiled dishware in machine and

lower doors. Depress the cycle start button,
machine will wash and rinse automatically.
When the rinse indicator light goes off the ma-
chine cycle is complete

9. Open doors and remove rack of clean ware.

For continuous operation repeat steps 2B19 &
2B10

10. Upon completion of ware cleaning move the

power toggle switch to the “OFF” position.

11. Refer to the cleaning procedures for proper

clean-up of the dishmachine.

12. A switch on the control panel labeled “Wash

Cycle” is provided for use when de-liming the
machine. When activated, this switch will keep
the machine in an indefinite wash cycle. This
feature can also be used to wash heavily soiled
ware on an extended wash cycle.

13. Report any unusual occurrences to qualified

service personnel.

The following cleaning procedures should be

done daily, at the end of the shift.
Cleaning Procedures, Daily

1. Remove all internal removable parts including

spray manifolds, scrap screens, drain overflow
tube and suction strainer.

2. Remove the end caps from the spray manifolds

and clean with the brush provided. Flush the
manifolds.

3. Flush scrap screens

4. Clean drain overflow tube.

PART 3 OPERATION & CLEANING INSTRUCTIONS

þ

NOTE:

V-cup seal on the drain overflow tube may
become gummed not allowing the overflow
tube to seal. This will cause the drain to leak
water. Remove any build-up on the V-cup
seal. When the seal becomes worn, replace
with part # D2-557.

WARNING:

!

Do not open the doors during the wash/
rinse cycle as hot water is being sprayed.
An interlock is provided to stop the wash/
rinse cycle if the doors are opened but hot
water may spray out if doors are opened
too quickly.

15