2.6 Panel SF 52W and SF 53W setup parameters

Normal MIG welding Setup -parameters

Name of parameter

Name on

display

Parameter

values

Factory

setting

Description

Pre Gas Time

PrG

0.0 – 9.9 s

0,0 s

Pre gas time in seconds

Post Gas Time

PoG

0.0 – 9.9 s

Aut

Post gas time in seconds or automatically
according to welding current (Aut)

Creep Start

Cr

OFF, on

OFF

Switch creep start on or off.

Creep Start Level

CrE

10 – 170%

50%

Percentage of wire feed speed:
10% slowed start
100% = no creep start function
170% accelerated start

Start Power

StA

-9 ... +9

0

Strength of start pulse

Post Current Time

PoC

-9 ... +9

0

Post current

Arc Voltage

Ard

OFF, on

OFF

on: Display shows arc voltage
OFF: Display shows pole voltage

Cable Length

CAb

std, 5 – 80m

std

Cable loss is calculated for optimal arc
control and for the Arc Voltage display

Synergic MIG -welding SETUP -parameters

Name of parameter

Name on

display

Parameter

values

Factory

setting

Description

Pre Gas Time

PrG

0.0 – 9.9 s

Syn

Pre gas time in seconds or automatically
according to synergic welding program
(Syn)

Post Gas Time

PoG

0.0 – 9.9 s

Syn

Post gas time in seconds or automatically
according to synergic welding program
(Syn)

Creep Start

Cr

OFF, on

OFF

Switch creep start on or off.

Creep Start Level

CrE

10 – 170%

50%

Percentage of wire feed speed:
10% slowed start
100% = no creep start function
170% accelerated start

Hot Start Level

Hot

-50 ... 75%

30%

Percentage of welding power:
-50% cold and +75% hot

Hot Start 2T Time

H2t

0.0 – 9.9 s

1.2 s

The duration of the hot start in seconds in
2T mode

Crater Fill End Level

CrL

10 – 250%

30%

The welding power at the end of the crater
fill stage as a percentage of the welding
power preset value

Crater Fill Start Level

CrS

10 – 250%

30%

The welding power at the beginning of
the crater fill stage as a percentage of the
welding power preset value

Crater Fill Time

CrT

0.0 – 9.9 s

2.0 s

The duration of the crater fill stage in
seconds (only in 2T mode)

Wise Fusion On

FUS

OFF, on

OFF

Switch Wise Fusion on/off (only in 1-MIG)

Wise Fusion Percent

FUP

10...60%

25%

Percentage of Wise Fusion (only in 1-MIG)

Penetration Level

PEn

-30 ... +30%

0%

Set the arc length where penetration
control begins (only in 1-MIG)

MiniLog On

ML

on, OFF

OFF

Switch on/off MiniLog

MiniLog Level

MLo

-99 ... +200%

50%

Set the minilog power level as a
percentage of the welding power

Advertising