TROUBLE SHOOTING GUIDE

No heat or heat too low

Probable Cause #1 ...................Dirty Filter.
Action .........................................Remove filter cartridge and clean.
Probable Cause #2 ...................Breaker at house off.
Action .........................................Reset breaker at house. Breaker can appear to be on

and one pole can be off. Turn breaker OFF then ON
twice.

Probable Cause #3 ...................Pump not primed.
Action .........................................Refer to the section of this manual on pump priming.
Probable Cause #4 ...................Improper line voltage.
Action .........................................Have a Licensed Electrician check the line voltage.

Spa Lights won't come on

Probable Cause #1 ...................Light bulb burned out.
Action .........................................Replace bulb (non-warranty).
Probable Cause #2 ...................Dirty connection.
Action .........................................Check to see if there is anything covering the

connection on the housing that holds the light bulb.

Pump will not prime

Probable Cause #1 ...................No water in pump.
Action .........................................Make sure water level in spa is correct.
Probable Cause #2 ...................Closed gate valves or blocked lines.
Action .........................................Open all gate valves. Check suction for blockage.
Probable Cause #3 ...................Pump surges, jets lose and gain power, loose union

or drain plug.

Action .........................................Check union on front or nose of pump to ensure

tightness. Check drain plugs to ensure tightness.

Jet(s) won't come on

Probable Cause #1 ...................Pump not primed.
Action .........................................Refer to the section of this manual on pump priming.
Probable Cause #2 ...................Gates valves closed.
Action .........................................Check to see if gate valves are in the correct position.

Check to see that pump is plugged in.

Probable Cause #3 ...................Water Diverter Valve not adjusted correctly.
Action .........................................Turn Water Diverter Valve until desired water flow is

obtained.

Probably Cause #4 ...................Individual jet is closed.
Action .........................................Turn the outer jet housing clockwise to turn jet on.

Low water flow

Probable Cause #1 ...................Dirty Filter.
Action .........................................Remove filter cartridge and clean.
Probable Cause #2 ...................Closed gate valves or blocked lines.
Action .........................................Open all gate valves.
Probable Cause #3 ...................Low voltage or incorrect voltage.
Action .........................................Have a Licensed Electrician check the line voltage.