Measurement Computing IOtech 640 Series User Manual

Page 72

Advertising
background image

Specifications are subject to change without notice.

11-2 Specifications

879592

IOtech 640 and 650 Series

High-pass filter (AC coupling cutoff):

640e; 640u: 1.0Hz

650e; 650u: 0.1Hz

Figure II. Measurement High Pass Filter Response

Input ranges:

640e; 640u: ±10V peak

650e; 650u: ±40V peak

Input protection: ±60V max without damage

Over-range indication: Software

Low-pass filter (software programmable per channel)

Figure III. 640 Measurement Delay vs. Frequency DC Coupled
Figure IV. 640 Measurement Delay vs. Frequency AC Coupled
Figure V. 650 Measurement Delay vs. Frequency DC Coupled
Figure VI. 650 Measurement Delay vs. Frequency AC Coupled

Type: Anti-Aliasing hardware 3-pole 360kHz, Software selectable FIR filter

Figure VII. Measurement Antialiasing Filter Performance

Any unwanted signals above 27MHz is lost in the noise floor of a 64k FFT.

Amplitude accuracy:

640e / 640u

650e / 650u

AC at 1kHz

0.07dB typ ±0.12dB max

0.1dB typ ±0.15dB max

DC

(0.03% of reading + 2mV)

(0.2% of reading + 15mV)

Amplitude -3dB: 0.49 x sample rate

Amplitude flatness: 0.05 dB typ ±0.10dB max DC to 20kHz

Figure X. Analog Measurement Flatness

Total harmonic distortion: -100dB typical 1kHz, -97dB typical 10kHz

Figure IX. Measurement THD+N

SFDR including harmonics: 108dB typical DC to 50kHz

SFDR (@-60dB): 128dB typical DC to 50kHz

Figure XI. 640 SFDR Full-Scale is +20dBV; Input is -40dBV

Figure XII. 650 SFDR Full-Scale is +29dBV; Input is -30dBV

Channel-to-channel crosstalk: <-100dB at 1kHz

Figure XIII. 640 Channel-to-Channel Cross Talk

Figure XIV. 650 Channel-to-Channel Cross Talk

Channel-to-channel phase matching:

640e; 640u: <0.04º / kHz + 0.08º

650e; 650u: <0.06º / kHz + 0.1º

Figure XV. 640 Phase-Matching vs. Frequency, AC-Coupled

Figure XVI. 650 Phase-Matching vs. Frequency, AC-Coupled

Advertising