Individual / simultaneous transfer jumper, Installing the cio-dda06/jr/16 – Measurement Computing CIO-DDA06/Jr/16 User Manual
Page 11
CIO-DDA06/Jr/16 User's Guide
Installing the CIO-DDA06/Jr/16
Disregard the numbers printed on the switch
When setting the base address, refer to the numbers printed in white on the printed circuit board.
Individual / simultaneous transfer jumper
The analog outputs can be jumpered so that new output data are held until all DAC registers have been loaded
with new data. The new data updates the voltage outputs when any of the board addresses are read.
A single jumper controls whether all of the DACs are either simultaneously transferred on a read (
XFER
), or
individually updated when the control register is written (
UPDATE
). Figure 3 shows the jumper block
configured for each update mode.
Individual updates
per channel
XFER
Jx
XFER
UPDATE
Jx
Simultaneous updates
of both channel
XFER
Jx
XFER
UPDATE
Jx
Figure 3. Individual / simultaneous update jumper
Use this feature to maintain a zero volt output after power-up by loading all DAC registers with mid-scale
values (8000h) and then updating.
Installing the CIO-DDA06/Jr/16
After you configure the board's switches and jumpers, you can install the CIO-DDA06/Jr/16 into your
computer. To install your board, follow the steps below.
Install the MCC DAQ software before you install your board
The driver needed to run your board is installed with the MCC DAQ software. Therefore, you need to install
the MCC DAQ software before you install your board. Refer to the Quick Start Guide for instructions on
installing the software.
1.
2.
3.
Turn your computer off, open it up, and insert your board into an available ISA slot.
Close your computer and turn it on.
To test your installation and configure your board, run the InstaCal utility you installed in the previous
section. Refer to the Quick Start Guide that came with your board
11