4 configuration, 1 dip switch settings, 1 common dip switches – Nevion EDFA-B-C 17dBm User Manual
Page 7: 2 constant power mode, 3 constant gain mode, 4configuration
EDFA-B-C 17dBm
Rev. B
nevion.com | 7
4
Configuration
4.1 Dip switch settings
The dip switches are also documented on the front of the EDFA
The following dip switches change the meaning of the other dip switches:
4.1.1 Common dip switches
Pos
Name
Function ON
Function OFF
Comment
1
G_P
Constant Gain
Constant Power
Fundamental working mode for
EDFA.
7
A_M
Autonomous
and/or
GYDA/DIP
control
Manual RS232
control
Set OFF to use the RS232 port in the
front of the EDFA to control
parameters like function (constant
power, gain or drive),
8
OVR
Dip switches
active
GYDA active
When ON, only dip switches can
change configuration. GYDA can only
monitor. To control with GYDA, set to
OFF.
4.1.2 Constant power mode
In this mode, dip switch 1, 7 and 8 is set ON.
Pos
Name
Function ON
Function OFF
Comment
2
S_T
SDI optimised
Telco optimised
Chooses between signal types
present on the fiber. For a low number
of SDI signals which might display
pathological signals (shifts in average
power), set dip ON. For many
channels with fast adaptation to
varying input levels, set dip OFF.
3
G3
Add 14dBm
Add 10dBm
These dip switches set the output
power, from a minimum of +10dBm to
a maximum of +17.5dBm (0.5dB
step).
4
G3
Add 2dBm
Add 0dBm
5
G2
Add 1dBm
Add 0dBm
6
G1
Add 0.5dBm
Add 0dBm
4.1.3 Constant gain mode
In this mode, dip switch 1 is set OFF, while switches 7 and 8 are set ON.
Pos
Name
Function ON
Function OFF
Comment
2
S_T
Not used
Not used
No effect in Constant Gain mode.
3
G3
Add 18dB
Add 10dB
These dip switches set the gain, from
a minimum of 10dB to a maximum of
25dB (1dB step).
4
G2
Add 4dB
Add 0dB
5
G1
Add 2dB
Add 0dB
6
G0
Add 1dB
Add 0dB