7 operation, 1 front panel led indicators – Nevion SDI-TD-MUX-4 User Manual

Page 21

Advertising
background image

SDI-TD-MUX-4 / SDI-TD-DMUX-4

Rev. N


nevion.com | 21

7 Operation

7.1 Front panel LED indicators

Figure 14 shows how the LEDs are located on the front panel.

Figure 14: Front panel view for the MUX. The DMUX LEDs are identical, except that the lower

LED refers to the HD input.

The table below shows how the front panel LEDs are to be interpreted. The four LEDs
correspond closely to the four GPI alarms explained in chapter 7.2.

Note that the term “in error” in the table means that there is either a missing signal (no carrier
detect) AND/OR the reclocker has not been able to lock to the incoming signal.

The term “operating normally” means that a signal has been detected (carrier detect on the
cable equalizer) AND the reclocker has been able to lock to the signal.

Diode

Description

Red LED

Orange LED

Green LED

No light

1

Card status

Power on,

FPGA not

configured

Not applicable

Power on and

FPGA

configured

No power

to board

2

Status of SD

inputs/streams

1 and 2

Both SD

inputs/streams

(1 and 2)

In error

One of the

inputs/streams

(1 or 2)
in error

Both

inputs/streams

(1 and 2)

operating

normally

No power

to board

3

Status of SD

inputs/streams

3 and 4

Both SD

inputs/streams

(3 and 4)

in error

One of the

inputs/streams

(3 or 4)
in error

Both

inputs/streams

(3 and 4)

operating

normally

No power

to board

4

(MUX)

Status of

HD OUT

Output failure

Laser failure

Output OK and

laser working

No power

to board

4

(DMUX)

Status of

HD IN

Input failure

N/A

Input OK

No power

to board

Advertising