NIStune Type 5 User Manual
Page 12
Type 5 Hardware Installation Manual
Page 11 of 15
4. FIT BOARD TO ECU
Make sure that the socket on the board lines up correctly with the header pins and insert the board.
For N14/B13 GA16DE ECUs you will need to reposition the crystal by extending the legs to the
crystal and its shielding and fold it over. Insulate the crystal from other components by wrapping the
shielding with electrical tape.
5. FIT PACKING
Remove the self adhesive backing from the foam rubber strip and fit it to the lid so that the board will
be held firmly in position once the lid is fitted. This is best done by sitting the rubber strip (sticky side
up) on top of the Simtek chip which is in the middle of the board, and then carefully fitting the lid.
Congratulations – you now have a fully tuneable ECU!