5.2.2 Serial and Ethernet Commands List

Table 2. Serial Commands List

Item Command

Example

Explanation

1

gst

gst

Get BUC status

2

sspaon

sspaon

Turn on SSPA

3

sspaoff

sspaoff

Turn off SSPA

4

sendipwr

sendipwr 192 168 100 2

Write master(PC) ip

5

sendiprd

sendiprd

Read master ip

6

sendportwr sendportwr 4001

Write master port

7

sendportrd sendportrd

Read master port

8

ipwr

ipwr 192 168 100 10

Write BUC ip

9

iprd

iprd

Read BUC ip

10

portwr

portwr 3000

Write BUC port

11

portrd

portrd

Read BUC port

12

gwwr

gwwr 192 168 100 1

Write BUC gateway

13

gwrd

gwrd

Read BUC gateway

14

macwr

macwr 00 11 22 33 44 55

Write BUC MAC address

15

macrd

macrd

Read BUC MAC address

16

smwr

smwr 255 255 255 0

Write subnet mask

17

smrd

smwr

Read subnet mask

18

setgain

setgain 6500

Set up Max. gain



5.2.3 Serial Mode Operation

For serial mode operation, connect a prepared RS232 cable between the MS 12-pin connector on
the BUC and the PC serial port as shown in Fig. 11. Refer to Table1 and Fig. 4 for RS232
connection.

Figure 11. RS 232 connection between BUC and PC