5.2.2 Serial and Ethernet Commands List
Table 2. Serial Commands List
Item Command
Example
Explanation
1
gst
gst
Get BUC status
2
sspaon
sspaon
Turn on SSPA
3
sspaoff
sspaoff
Turn off SSPA
4
sendipwr
sendipwr 192 168 100 2
Write master(PC) ip
5
sendiprd
sendiprd
Read master ip
6
sendportwr sendportwr 4001
Write master port
7
sendportrd sendportrd
Read master port
8
ipwr
ipwr 192 168 100 10
Write BUC ip
9
iprd
iprd
Read BUC ip
10
portwr
portwr 3000
Write BUC port
11
portrd
portrd
Read BUC port
12
gwwr
gwwr 192 168 100 1
Write BUC gateway
13
gwrd
gwrd
Read BUC gateway
14
macwr
macwr 00 11 22 33 44 55
Write BUC MAC address
15
macrd
macrd
Read BUC MAC address
16
smwr
smwr 255 255 255 0
Write subnet mask
17
smrd
smwr
Read subnet mask
18
setgain
setgain 6500
Set up Max. gain
5.2.3 Serial Mode Operation
For serial mode operation, connect a prepared RS232 cable between the MS 12-pin connector on
the BUC and the PC serial port as shown in Fig. 11. Refer to Table1 and Fig. 4 for RS232
connection.
Figure 11. RS 232 connection between BUC and PC
© 2014 Norsat International Inc.
Page 16 of 25