Delta Electronics Ignition Coil IGT004 User Manual

Ignition coil, Igt004 type, Mechanical dimension

Advertising
background image

Mechanical Dimension:

o

o

Operation temperature: -40C to +105C

o

o

Storage temperature: -20C to +85C
Input voltage: 240 Vdc
No-load voltage: 14KV min.
Insulated with epoxy resin

Recommended Circuit:

1

2

4

3

PRI

SEC

Schematic :

Unit: mm

IGT004 Type

DELTA ELECTRONICS, INC.

(TAOYUAN PLANT CPBG)

23.0 Max.

0.5x1.0

23.0 0.5

13.7 0.5

1

4

16.0 0.5

2

3

28.5 Max.

25.0 Max.

4.0 0.5

+

-

240 Vdc

SUPPLY

DC

SW1

C1

2.2nf

SW2

1

2

T1

OUTPUT

50pf

4

3

72

Via the system-provided input voltage 230-240V, the high voltage coil is stimulated
and gives the voltage output between 14KVo-p & 25KVo-p to start up the ignition system
of the gas furnance or the molecule ozonization of air cleaning M/C.

Features

Gas Igniter
Oil Igniter
Air Cleaner
Electronic Ozonizer

Applications

Electrical Characteristics:

252, SAN YING ROAD, KUEISAN INDUSTRIAL ZONE, TAOYUAN SHIEN, 333, TAIWAN, R.O.C.
TEL: 886-3-3591968; FAX: 886-3-3591991
http://www.deltaww.com

PRIMARY

INDUCTANCE (uH)

o

AT 25 C, 65%RH, INDUCTANCE TESTED@1KHz/1V

PRIMARY

SECONDARY

PRIMARY

SECONDARY

WEIGHT

PART NO.

INDUCTANCE (uH)

INDUCTANCE (mH)

DCR (m ) MAX.

DCR ( ) MAX.

IGT-004

22.0 25%

290.0 25%

55

500

32g

C2

Ignition Coil

Advertising
Table of contents